This is static sealing for modest pressures and joints that are not opened often. Sealing follows the compression ratio, not the amount of sealant. Too little compression leaves a gap, too much takes a permanent set and stops recovering, so the installed thickness has to land inside a defined window and is verified by test rather than by inspection.
installed by threaded in, coating filling the clearance.
Do not solvent-clean the thread before assembly; residue interferes with adhesion.
| Drive Type | Torx Plus |
|---|---|
| Standard | GB/T 197, GB/T 4208 (IP rating) |
| Installation | threaded in, coating filling the clearance |
| Typical substrate | housing threads and end caps |
| Key inspections | leak tightness, coating coverage, prevailing torque |
Coverage and thickness are checked microscopically, with gauging to confirm the coating does not block the thread.We recommend a pilot assembly at the actual torque and mating part before locking the process parameters for volume.